Plug PCs: compare computers from every brand
← Back to catalogWhere to buyAPC ↗checking retailers…
APC
APC Back-UPS CS 350VA, 120V, 6 NEMA outlets (4 surge)
SKU
BK350GTIN731304016298Battery4…6 year(s)
Weight12.5 lb
Specifications 64 normalized
Memory & storage
- Storage altitude
- 0…50000 ft (0…15240 m)
- Storage relative humidity
- 0…95 %
- Battery capacity
- 7.0 Ah
- Ambient air temperature for storage
- 5…113 °F (-15…45 °C)
Display
- Control panel
- LED status display with on line : on battery : replace battery and overload indicators
Connectivity
- Empty battery slot
- 0
- Type of USB power supply
- None
- Number of power module filled slots
- 0
- Number of power module free slots
- 0
- Input connection
- NEMA 5-15P
- Output connection
- 3 NEMA 5-15R surge
- USB compatible
- Yes
Power & battery
- Replacement battery
- RBC2
- Battery type
- Lead-acid internal included
Lead-Acid battery - Battery voltage
- 12 V
- Battery graph comment
- This graph is based on actual measured runtime data. All measurements were taken with new, fully charged batteries and a balanced resistive load (PF = 1.0). Actual runtimes may vary from the values of this graph. Actual runtimes are dependent on several variables including battery age, battery charge level, environmental conditions and characteristics of the connected load.
- Included battery module
- 0
- Battery Life
- 4…6 year(s)
- Battery charging power
- 10 W rated
- Rated power in W
- 210 W
- Rated power in VA
- 350 VA
- Maximum configurable power in VA
- 350 VA
- Maximum configurable power in W
- 210 W
- Typical recharge time
- 8 h
Physical & build
- Product weight
- 12.52 lb(US) (5.68 kg)
- Weight
- 12.52 lb(US) (5.68 kg)
- Dimensions
- 3.6 x 6.5 x 11.2 in (W x H x D)
- Color
- Beige
Warranty & support
- Warranty (in months)
- 36 UPS
12 Battery
Other
- Main input voltage
- 120 V AC 1 phase
- Efficiency at full load
- 98...140 V
- Input frequency
- 50/60 Hz +/- 3 Hz auto-sensing
- Output voltage
- 120 V AC 1 phase
- Maximum output current
- 10 A
- Transfer time
- 8ms typical : 12ms maximum
- UPS topology
- Standby
- Waveform type
- Stepped approximation to a sinewave
- Output frequency
- 50/60 Hz +/- 3 Hz sync to mains
- Alarm
- Alarm when on battery : distinctive low battery alarm : overload continuous tone alarm
- UPS connectivity
- USB port
- Let through voltage rating
- 300 V
- Surge energy rating
- 1020 J
- Noise filtering
- Full time multi-pole noise filtering : 5% IEEE surge let-through : zero clamping response time : mee
- Cable length
- 6 ft (1.8 m)
- Number of cables
- 1
- Height
- 6.5 in (165 mm)
- Width
- 3.6 in (91 mm)
- Depth
- 11.2 in (284 mm)
- Mounting location
- Front
- Mounting preference
- No preference
- Mounting mode
- Not rack-mountable
Tower - Two post mountable
- 0
- Provided equipment
- CD with software
Cord management straps
User Manual
USB cable - Redundant
- No
- Range of product
- Back-UPS
- Product or component type
- Uninterruptible power supply (UPS)
- Product certification
- California (CEC) Battery Charger
ENERGY STAR V2.0 (USA)
TÜV - Ambient air temperature for operation
- 32…104 °F (0…40 °C)
- Relative humidity
- 0…95 %
- Acoustic level
- 45 dBA
- Heat dissipation
- 20 Btu/h
- Operating altitude
- 0...10000 ft
- Extendable runtime
- 0
- RBC quantity
- 1
Price history