APC

APC NetShelter Metered Rack PDU, 0U, 3PH, 11kW 230V 16A or 11kW 230V 16A, 36 C13 and 6 C19 outlets, IEC 309 3P+N+PE cord

ModelAP8881GTIN731304277071
Weight14.1 lb

Specifications 36 normalized

Memory & storage
Storage Relative Humidity
5…95 %
Storage altitude
0…50000 ft (0…15240 m)
Load Capacity
11000 VA
Ambient Air Temperature for Storage
-13…149 °F (-25…65 °C)
Connectivity
Input Connection Type
IEC 60309 16 A 3P+N+PE
IEC 60309 20 A 3P+N+PE
Power & battery
Number of power socket outlets
36 IEC 60320 C13
6 IEC 60320 C19
Physical & build
Net Weight
14.07 lb(US) (6.38 kg)
Dimensions
2.2 x 70.5 x 1.7 in (W x H x D)
Warranty & support
Warranty (in months)
24
Other
Presentation
APC Metered Rack Power Distribution Units (PDUs) provide active metering to enable energy optimization and circuit protection. User-defined alarm thresholds mitigate risk with real-time local and remote alerts to warn of potential circuit overloads. Metered Rack PDUs provide power utilization data to allow Data Center Managers to make informed decisions on load balancing and right sizing IT environments to lower total cost of ownership. Metered Rack PDUs include real power monitoring, a temperature/humidity sensor port, locking IEC receptacles, and ultra low profile circuit breakers. Users can access and configure Metered Rack PDUs through secure Web, SNMP, or Telnet Interfaces which are complimented by APC Centralized Management platforms using InfraStruxure Central, Operations, Capacity, and Energy Efficiency.
Product or Component Type
PDU
Main Input Voltage
400 V 3 phase
Input current limits
16 A
Input Frequency
50/60 Hz
Main Output Voltage
230 V
Line Rated Current
16 A
Max current draw
16 A
Max line current
16 A
PDU Type
Metered
Protection Type
Without circuit breaker
Number of rack unit
0U
Number of cables
1
Cable length
5.97 ft (1.82 m)
Provided Equipment
Installation guide
Rack Mounting brackets
Serial configuration cable
Safety guide
Mounting Location
Side
Mounting Mode
Rack-mounted
Mounting position
Vertical
Height
70.5 in (1791 mm)
Width
2.2 in (55 mm)
Depth
1.7 in (44 mm)
Product Certifications
VDE
Standards
CSA C22.2 No. 60950
IEC 60950
UL 60950-1
Relative Humidity
5…95 %
Operating altitude
0...10000 ft
Ambient Air Temperature for Operation
23…140 °F (-5…60 °C)
Country of origin
IN