APC NetShelter Metered Rack PDU, 2G, 0U, 20A, 208V, 18 C13 and 2 C19 outlets, L6-20 inlet
Model
AP8858NA3GTIN731304277040Weight6.5 lb
Specifications 36 normalized
Memory & storage
- Storage Relative Humidity
- 5…95 %
- Storage altitude
- 0…50000 ft (0…15240 m)
- Load Capacity
- 3300 VA
- Ambient Air Temperature for Storage
- -13…149 °F (-25…65 °C)
Connectivity
- Input Connection Type
- NEMA L6-20P
Power & battery
- Number of power socket outlets
- 18 IEC 60320 C13
2 IEC 60320 C19
Physical & build
- Net Weight
- 6.46 lb(US) (2.93 kg)
- Dimensions
- 2.2 x 35.5 x 1.7 in (W x H x D)
Warranty & support
- Warranty (in months)
- 24
Other
- Presentation
- APC Metered Rack Power Distribution Units (PDUs) provide active metering to enable energy optimization and circuit protection. User-defined alarm thresholds mitigate risk with real-time local and remote alerts to warn of potential circuit overloads. Metered Rack PDUs provide power utilization data to allow Data Center Managers to make informed decisions on load balancing and right sizing IT environments to lower total cost of ownership. Metered Rack PDUs include real power monitoring, a temperature/humidity sensor port, locking IEC receptacles, and ultra low profile circuit breakers. Users can access and configure Metered Rack PDUs through secure Web, SNMP, or Telnet Interfaces which are complimented by APC Centralized Management platforms using InfraStruxure Central, Operations, Capacity, and Energy Efficiency.
- Product or Component Type
- PDU
- Main Input Voltage
- 200 V
208 V
230 V
240 V - Input current limits
- 20 A
- Input Frequency
- 50/60 Hz
- Main Output Voltage
- 208 V
- Line Rated Current
- 16 A
- permissible voltage
- 100…240 V
- Max current draw
- 16 A
- PDU Type
- Metered
- Protection Type
- Without circuit breaker
- Number of rack unit
- 0U
- Number of cables
- 1
- Cable length
- 9.5 ft (2.9 m)
- Provided Equipment
- Installation guide
Locking input power cord
Rack Mounting brackets
Serial configuration cable
Safety guide - Mounting Location
- Side
- Mounting Mode
- Rack-mounted
- Mounting position
- Vertical
- Height
- 35.5 in (902 mm)
- Width
- 2.2 in (56 mm)
- Depth
- 1.7 in (44 mm)
- Product Certifications
- METI Denan
VDE - Standards
- CSA C22.2 No. 60950
IEC 60950
UL 60950-1 - Relative Humidity
- 5…95 %
- Operating altitude
- 0...10000 ft
- Ambient Air Temperature for Operation
- 23…140 °F (-5…60 °C)
- Country of origin
- IN