APC NetShelter Metered Rack PDU, 2G, 0U, 30A, 100V to 120V, 24 NEMA 5-20R outlets
Model
AP8832GTIN731304307334Weight14.7 lb
Specifications 38 normalized
Memory & storage
- Storage Relative Humidity
- 5…95 %
- Storage altitude
- 0…50000 ft (0…15240 m)
- Load Capacity
- 2880 VA
- Ambient Air Temperature for Storage
- -13…149 °F (-25…65 °C)
Connectivity
- Input Connection Type
- NEMA L5-30P
Power & battery
- Number of power socket outlets
- 24 NEMA 5-20R
Physical & build
- Net Weight
- 14.70 lb(US) (6.67 kg)
- Dimensions
- 2.2 x 70.5 x 1.7 in (W x H x D)
Warranty & support
- Warranty (in months)
- 24
Other
- Presentation
- APC Metered Rack Power Distribution Units (PDUs) provide active metering to enable energy optimization and circuit protection. User-defined alarm thresholds mitigate risk with real-time local and remote alerts to warn of potential circuit overloads. Metered Rack PDUs provide power utilization data to allow Data Center Managers to make informed decisions on load balancing and right sizing IT environments to lower total cost of ownership. Metered Rack PDUs include real power monitoring, a temperature/humidity sensor port, locking IEC receptacles, and ultra low profile circuit breakers. Users can access and configure Metered Rack PDUs through secure Web, SNMP, or Telnet Interfaces which are complimented by APC Centralized Management platforms using InfraStruxure Central, Operations, Capacity, and Energy Efficiency.
- Product or Component Type
- PDU
- Main Input Voltage
- 100 V
120 V - Input current limits
- 30 A
- Input Frequency
- 50/60 Hz
- Main Output Voltage
- 100 V
120 V - Line Rated Current
- 24 A
- permissible voltage
- 100…120 V
- PDU Type
- Metered
- Protection Type
- Circuit breaker
- Number of rack unit
- 0U
- Number of cables
- 1
- Cable length
- 9.5 ft (2.9 m)
- Provided Equipment
- Installation guide
Rack Mounting brackets
Serial configuration cable
Safety guide - Mounting Location
- Side
- Mounting Mode
- Rack-mounted
- Mounting position
- Vertical
- Height
- 70.5 in (1791 mm)
- Width
- 2.2 in (55 mm)
- Depth
- 1.7 in (44 mm)
- Product Certifications
- cUL Listed
PSE
UL Listed - Standards
- FCC Part 15 class A
ICES-003
UL 60950-1 - Relative Humidity
- 5…95 %
- Operating altitude
- 0...10000 ft
- Ambient Air Temperature for Operation
- 23…140 °F (-5…60 °C)
- Category
- 80230-IG SEBA TO SEUSA
- Discount Schedule
- BMS1
- Returnability
- No
- Country of origin
- PH