Plug PCs: compare computers from every brand
← Back to catalogWhere to buyAPC ↗checking retailers…
APC
APC NetShelter Switched Rack PDU, 0U, 20A/208V, 16A/230V, 7 C13 and 1 C19 outlets
Model
AP8958GTIN731304277101Weight7.1 lb
Specifications 34 normalized
Memory & storage
- Storage Relative Humidity
- 5…95 %
- Storage altitude
- 0…50000 ft (0…15240 m)
- Load Capacity
- 3300 VA
- Ambient Air Temperature for Storage
- -13…149 °F (-25…65 °C)
Connectivity
- Input Connection Type
- IEC 60320 C20
Power & battery
- Number of power socket outlets
- 7 IEC 60320 C13
1 IEC 60320 C19
Physical & build
- Net Weight
- 7.12 lb(US) (3.23 kg)
- Dimensions
- 2.2 x 38.9 x 1.8 in (W x H x D)
Warranty & support
- Warranty (in months)
- 24
Other
- Presentation
- APC Switched Rack Power Distribution Units (PDUs) enable advanced, user-customizable power control and active monitoring. Remote outlet level controls allow power on/off functionality for power recycling to remotely reboot equipment and restrict unauthorized use of individual outlets. Power sequencing delays allow users to define the order in which to power up or down attached equipment. Avoid circuit overload during power recovery and extend uptime of critical equipment by prioritizing the load shedding. Current metering provides real-time remote monitoring of connected loads. Switched Rack PDUs include real power monitoring, a temperature/humidity sensor port, locking IEC receptacles, and low profile circuit breakers. User-defined alarms warn of potential circuit overloads before critical IT failures occur. Users can access, configure, and control Switched Rack PDUs through secure Web, SNMP, or Telnet Interfaces and is complimented by APC Centralized Management platforms using InfraStruxure Central, Capacity Manager and Change Manager.
- Product or Component Type
- PDU
- Main Input Voltage
- 200 V
208 V
230 V - Input current limits
- 20 A
- Input Frequency
- 50/60 Hz
- Main Output Voltage
- 100 V
200 V
208 V
230 V - Line Rated Current
- 16 A
- permissible voltage
- 100…240 V
- Max current draw
- 16 A
- PDU Type
- Switched
- Protection Type
- Without circuit breaker
- Number of rack unit
- 0U
- Provided Equipment
- Installation guide
Rack Mounting brackets
Serial configuration cable
Safety guide - Mounting Location
- Side
- Mounting Mode
- Rack-mounted
- Mounting position
- Vertical
- Height
- 38.9 in (988 mm)
- Width
- 2.2 in (56 mm)
- Depth
- 1.8 in (46 mm)
- Product Certifications
- cUL Listed
PSE
UL Listed
VCCI Class A
VDE - Standards
- EN 55022 Class A
EN 55024
EN 61000-3-2
EN 61000-3-3
FCC Part 15 class A
ICES-003 - Relative Humidity
- 5…95 %
- Operating altitude
- 0...10000 ft
- Ambient Air Temperature for Operation
- 23…140 °F (-5…60 °C)
- Country of origin
- IN
Price history
loading…