APC
APC Rack PDU, 2G, metered by outlet, with switching, 0U, 30A, 100V to 120V, 24 NEMA 5-20R sockets
Model
AP8632GTIN731304307457Weight17.8 lb
Specifications 34 normalized
Memory & storage
- Storage Relative Humidity
- 5…95 %
- Storage altitude
- 0…50000 ft (0…15240 m)
- Load Capacity
- 2880 VA
- Ambient Air Temperature for Storage
- -13…149 °F (-25…65 °C)
Connectivity
- Input Connection Type
- NEMA L5-30P
Power & battery
- Number of power socket outlets
- 24 NEMA 5-20R
Physical & build
- Net Weight
- 17.75 lb(US) (8.05 kg)
- Dimensions
- 2.2 x 72.008 x 2.008 in (W x H x D)
Warranty & support
- Warranty (in months)
- 24
Other
- Presentation
- APC Metered by Outlet with Switching Rack Power Distribution Units (PDUs) enable advanced, user-customizable power control and individual outlet power metering. Remote outlet level controls allow power on/off functionality for power recycling to reboot locked-up equipment and to avoid unauthorized use of individual outlets. Power sequencing delays allow users to define the order in which to power up or down attached equipment. Avoid circuit overload during power recovery and extend uptime of critical equipment by prioritizing the load shedding. Current metering provides real-time remote monitoring of connected loads. Switched Rack PDUs include real power monitoring, a temperature/humidity sensor port, and locking IEC receptacles. User-defined alarms warn of potential circuit overloads before critical IT failures occur. Users can access, configure, and control Switched rack PDUs through secure Web, SNMP, or Telnet Interfaces and is complimented by Struxureware for Data Centers using Data Center Expert and Data Center Operations with Capacity and Change modules.
- Product or Component Type
- PDU
- Main Input Voltage
- 100 V
120 V - Input current limits
- 30 A
- Input Frequency
- 50/60 Hz
- Main Output Voltage
- 100 V
120 V - Line Rated Current
- 24 A
- permissible voltage
- 100…120 V
- PDU Type
- Switched metered outlet
- Protection Type
- Circuit breaker
- Number of rack unit
- 0U
- Number of cables
- 1
- Cable length
- 9.5 ft (2.9 m)
- Provided Equipment
- Installation guide
Rack Mounting brackets
Serial configuration cable
Safety guide - Mounting Location
- Side
- Mounting Mode
- Rack-mounted
- Mounting position
- Vertical
- Height
- 72.008 in (1829 mm)
- Width
- 2.2 in (55 mm)
- Depth
- 2.008 in (51 mm)
- Product Certifications
- cUL Listed
PSE
UL Listed - Standards
- FCC Part 15 class A
ICES-003
UL 60950-1 - Relative Humidity
- 5…95 %
- Operating altitude
- 0...10000 ft
- Ambient Air Temperature for Operation
- 23…140 °F (-5…60 °C)