Plug PCs: compare computers from every brand
← Back to catalogWhere to buyAPC ↗checking retailers…
APC
Rack PDU 2G, Metered-by-Outlet, ZeroU, 11.0kW, 230V, (21) C13 & (3) C19
Model
AP8481GTIN731304317609Weight18.1 lb
Specifications 35 normalized
Memory & storage
- Storage Relative Humidity
- 5…95 %
- Storage altitude
- 0…50000 ft (0…15240 m)
- Load Capacity
- 11000 VA
- Ambient Air Temperature for Storage
- -13…149 °F (-25…65 °C)
Connectivity
- Input Connection Type
- IEC 60309 16 A 3P+N+PE
IEC 60309 20 A 3P+N+PE
Power & battery
- Number of power socket outlets
- 21 IEC 60320 C13
3 IEC 60320 C19
Physical & build
- Net Weight
- 18.10 lb(US) (8.21 kg)
- Dimensions
- 2.2 x 72.008 x 2.008 in (W x H x D)
Warranty & support
- Warranty (in months)
- 24
Other
- Presentation
- APC Metered by Outlet Rack Power Distribution Units (PDUs) provide individual outlet power metering to enable energy optimization and circuit protection. Current metering provides real-time remote monitoring of connected loads. Metered by Outlet Rack PDUs provide power utilization data to allow Data Center Managers to make informed decisions on load balancing and right sizing IT environments to lower total cost of ownership. Metered by Outlet Rack PDUs include real power monitoring, a temperature/humidity sensor port, locking IEC receptacles, and ultra low profile circuit breakers. Users can access and configure Metered by Outlet Rack PDUs through secure Web, SNMP, or Telnet Interfaces which are complimented by APC Centralized Management platforms using InfraStruxure Central, Operations, Capacity, and Energy Efficiency.
- Product or Component Type
- PDU
- Main Input Voltage
- 400 V 3 phase
- Input current limits
- 16 A
- Input Frequency
- 50/60 Hz
- Main Output Voltage
- 230 V
- Line Rated Current
- 16 A
- Max current draw
- 16 A
- Max line current
- 16 A
- PDU Type
- Metered outlet
- Number of rack unit
- 0U
- Number of cables
- 1
- Cable length
- 5.9 ft (1.8 m)
- Provided Equipment
- CAN Port Terminator
Installation guide
Rack Mounting brackets
Safety guide
Serial configuration cable - Mounting Location
- Side
- Mounting Mode
- Rack-mounted
- Mounting position
- Vertical
- Height
- 72.008 in (1829 mm)
- Width
- 2.2 in (56 mm)
- Depth
- 2.008 in (51 mm)
- Product Certifications
- cUL Listed
UL Listed
VDE - Standards
- EN 55022 Class A
EN 55024
EN 61000-3-2
EN 61000-3-3
FCC Part 15 class A
ICES-003 - Relative Humidity
- 5…95 %
- Operating altitude
- 0...10000 ft
- Ambient Air Temperature for Operation
- 23…140 °F (-5…60 °C)
- Country of origin
- IN
Price history
loading…