Eaton

Eaton Tripp Lite series UPS VS450T 450VA

SKUVS450TGTIN037332212887
Weight8.2 lb

Specifications 74

Memory & storage
Storage Temperature
5° to 113 °F (-15° to 45 °C )
Output Capacity (kVA)
0.45
Output Capacity (Watts)
240
Output Capacity Details
3.8A @ 120V. (LINE MODE) 110%+/- 10% @ 5 minutes
(BATTERY MODE) 110% +/- 10% @ 5 seconds
Output Capacity (VA)
450
Connectivity
Network Management Cards Details
Network management not supported
Communication interface
None
UPS Input Connection Type
5-15P
Power & battery
Battery type
Valve Regulated Lead Acid (VRLA)
High Voltage Transfer to Battery Power
145
Low Voltage Transfer to Battery Power
89
Output AC waveform (battery mode)
PWM sine wave
Output Voltage Regulation(Battery Mode)
120V (+/- 10%)
Rechargeable Battery
8 hours (10% to 90%)
Output power factor
0.53
UPS Power Module Dimensions
5.6 × 4 × 11.8
Power Mode Transfer Time
6 milliseconds
Physical & build
Product Weight
8.2 lb
Rack size
0U
Housing material
ABS
Form Factor
Tower
Warranty & support
Recommended Electrical Service
15A 120V
Nominal Input Voltage Supported
120V AC
More details
Product Name
Eaton Tripp Lite series UPS
Catalog Number
VS450T
UPC
037332212887
Product Length/Depth
13.5 in
Product Height
8.7 in
Product Width
5.5 in
Compliances
RoHS
FCC Class A
Certifications
CSA certified
UL 1778
NOM
Global Catalog
VS450T
Product Type
UPS
Topology
Line-interactive
VA rating
450 VA
Package contents
VS450T 450VA 240 W Line-Interactive UPS with 4 Outlets Owner's manual
Nominal frequency
60 Hz
Input frequency range
60 Hz
Receptacle
5-15R
Output nominal voltage
110 / 120V
Electric current - max
5A 5
Runtime at half load
5 min
Operating Humidity
0-90% non-condensing
Input Plug Type
NEMA 5-15P
Output Receptacles
5-15R
Nominal Output Voltage
110V
115V
120V
Phase (input)
Single-phase
Runtime at full load
0.5 min. (240 W)
Dc Voltage
12
Operating Temperature
32° to 104 °F (0° to 40 °C)
Input Circuit Breakers
5A
Undervoltage Correction
Input voltages between 89 and 108 are boosted by 18%
Application
Home/Office Desktop Retail/Point of Sale Hospitality
Switch configuration
Controls off/on power status
AC suppression joule rating
316
Output AC waveform (AC mode)
Sine wave
Primary UPS Depth (mm)
300 mm
Primary UPS Height (mm)
142 mm
Primary UPS Width (mm)
102 mm
AC Suppression Response Time
Instantaneous
Audible Alarms
Audible alarm indicates low-battery, fault, overload and replace-battery status
LED Indicators
3 LEDs indicate online mode (green), battery mode (yellow) and fault mode (red)
Output Voltage Regulation (Line Mode)
120V (+9%, -12%)
Overvoltage Correction
Input voltages between 132 and 145 are reduced by 15%
Nominal Voltage Details
120V sinusoidal in line mode and 120V PWM in battery mode
Maximum Input Amps
5
UPS Input Cord Length (m)
1.5
Total Outlets
4
EMI AC Noise Suppression
EMI / RFI AC Noise Suppression
Input Nominal Voltage
120V AC
UPS Output Receptacles
3 UPS outlets, 1 surge-only outlet
High Availability UPS Features
Automatic voltage regulation (AVR)
Surge/noise protection
Features
  • Frequency Rating Details
  • Voltage Regulation Description